Tm:YAP Resonantly Pumped Ho:YLF Passively Q-Switched Laser
This paper reports resonantly pumped continuous wave and passively Q-Switched Ho:YLF lasersFirst, a Tm:YAP continuous wave laser with the output wavelength of 1940 nm is realized as a pump source for resonantly pumped Ho:YLF laser. Second, by using Ho:YLF crystal as the gain medium, a Ho:YLF continuous wave laser with the output wavelength of 2065.26 nm is realized. The maximum output power of 3.68 W was obtained under 6.02 W absorbed pump power with the slope efficiency and optical-to-optical conversion efficiency of 75.83% and 61.10% respectively. Last, by using Cr 2+:ZnS crystal as the saturable absorber, a Ho:YLF Passively Q-Switched laser with the output wavelength of 2053 nm is realized. The maximum average output power of 1.76 W was obtained under 5.26W absorbed pump power with the slope efficiency and optical-to-optical conversion efficiency of 43.50% and 33.52% respectively. At this time, the pulse width is 46.55 ns, the pulse repetition rate is 2.56 kHz, the single pulse energy is 686.7 μJ, and the peak power is 14.75 kW.
2 μm Solid State Laser
在过去的几十年里,激光技术经历了迅速的发展,并已成为现代科技不可或缺的一部分。特别是2 μm固体激光器,由于其独特的波长范围,能够在许多领域中发挥重要作用。2 μm波段激光具备良好的大气透过性和对生物组织的高吸收率,使其在激光通信、遥感探测、医疗手术及材料加工等多个应用领域中展示出其独特的优势
在实现2 μm波长激光输出的领域中,目前主要有三种技术途径被广泛探索和研究,分别为光学参量振荡器
在本文中我们以自建的Tm:YAP激光器作为泵浦源,研究了连续波和被动调Q脉冲Ho:YLF激光器的输出特性。在Ho:YLF连续波激光器中,获得中心波长为2065.26 nm、最大输出功率为3.68 W的连续激光输出,其斜率效率为75.83%。在Ho:YLF被动调Q激光器中,获得中心波长为2053 nm、最大平均输出功率为1.76 W的脉冲激光输出,其斜率效率为43.50%。
为了实现谐振泵浦Ho:YLF激光器,首先搭建了1940 nm Tm:YAP高功率激光器作为Ho:YLF激光器的泵浦源,其实验装置如
Ho:YLF激光器的实验装置图如
实验中使用激光功率计(北京物科光电,LP-3B20)测量了该激光器的输出功率。
实验中利用波长计(Bristol Instruments, 771A)测量最大输出功率下的光谱,如
图5. Tm:YAP激光器光束质量:(a) Pout= 2 W;(b) Pout= 5 W;(c) Pout= 10 W;(d) Pout= 19 W
为进一步探究Tm:YAP激光器激光输出的稳定性,在最大输出功率下,利用激光功率计对30 min之内的输出功率进行了取样操作,首先,将记录的步长设置为1 s,一共有1800个数据点可供参考,数据点的多样性也会保证结论的严谨性。如
基于上述实验数据,可确定此Tm:YAP连续波激光器完全符合作为Ho:YLF激光器的泵浦源。
在实验中,首先在没有插入可饱和吸收体的情况下,记录了Ho:YLF激光器连续波输出特性,实验中测得Ho:YLF晶体对泵浦光的吸收效率为49%,为了更加准确的表现出Ho:YLF晶体的输出特性,所以使用吸收泵浦功率来描述激光器的输出特性。Ho:YLF激光器的连续输出功率与吸收泵浦的关系如
实验中使用波长计来测量Ho:YLF激光器在最大输出功率下的输出光谱。如
实验中使用光束质量分析仪(DataRay, WinCamD-IR-BB)对输出激光的能量分布进行测量,首先利用焦距为100 mm的会聚透镜对光束进行会聚,之后用光束质量分析仪记录激光沿光轴方向不同位置处的光斑尺寸,从而计算出x轴方向和y轴方向上的光束质量因子M2。由
在被动调Q实验中,首先利用Ho:YLF连续波激光器的腔参数,其次通过改变可饱和吸收体Cr2+:ZnS在谐振腔内的位置,研究脉冲激光的输出特性。当距离d分别设置为10 mm、35 mm和60 mm时,平均输出功率与吸收泵浦功率的关系如
图11. 不同d下Ho:YLF被动调Q激光器的输出特性:(a) 脉冲宽度;(b) 脉冲重复频率;(c) 单脉冲能量;(d) 峰值功率
当d = 60 mm时,在最大平均输出功率下记录了单脉冲轮廓和脉冲序列。如
实验中采用单色仪(Zolix, Omni-λ 300)测量了d = 60 mm时脉冲激光的输出光谱,如
实验中使用光束质量分析仪测量了d = 60 mm时,最大平均输出功率下脉冲激光的能量分布,由
图12. D = 60 mm时,Ho:YLF被动调Q激光器:(a) 单脉冲轮廓;(b) 脉冲序列
利用激光功率计对30 min之内的Ho:YLF被动调Q激光器的最大平均输出功率进行了取样观察,如
首先,以Tm:YAP晶体作为激光增益介质,采用Z型腔结构,在注入泵浦功率为80 W时,实现了最大输出功率为19.16 W,中心波长在1940 nm的激光输出,其斜率效率和光光转换效率分别达到了31.77%和23.86%,在最大输出功率下,功率稳定性为0.32%,且在2 W至19 W的输出功率范围内,光束质量因子从1.12增加至2.47。以Tm:YAP激光器对L型腔结构的Ho:YLF激光器进行谐振泵浦,在吸收泵浦功率为6.02 W时,实现了最大输出功率为3.68 W,中心波长为2065.26 nm的激光输出,其斜率效率和光光转换效率分别达到了75.83%和61.10%,在最大输出功率下,功率稳定性为0.5%,输出激光水平方向和竖直方向光束质量因子分别为 = 1.10, = 1.12。最后,将插入可饱和吸收体放置在距离输出镜60 mm时,在吸收泵浦功率为5.26 W时,获得最大平均输出功率1.76 W,中心波长为2053 nm的脉冲激光输出,相应的斜率效率和光光转换效率分别为43.50%和33.52%。此时脉冲宽度为46.55 ns,脉冲重频为2.56 kHz,单脉冲能量为686.7 μJ,峰值功率为14.75 kW,功率稳定性为0.34%,输出激光水平方向和竖直方向光束质量分别为 = 1.26, = 1.30,由此可知,当可饱和吸收体上的振荡光班越小时,脉冲激光的输出特性越好。
*通讯作者。